Evi air-to-water heat pump with Copeland compressor, R410A refrigerant, swept heat exchanger

Low temperature EVI air to water heat pump water heater, EVI air source heat pump,  with Copeland compressor and R410a refrigerant, SWEP plate type heat exchanger, lowest working temperature can reach -25 deg C.* Copeland compressor & R410a refrigerant;* Stainless steel 304 f

Featured Products

Low temperature EVI air to water heat pump water heater, EVI air source heat pump,  with Copeland compressor and R410a refrigerant, SWEP plate type heat exchanger, lowest working temperature can reach -25 deg C.
* Copeland compressor & R410a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* "SWEP" plate type heat exchanger;
* Chinese No.1 brand "Sanhua" 4-way valve;
* Schneider AC contactor and relay;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* KONNEN LCD controller;
* Delivery time: 25~30 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Evi Air to Water Heat Pump with Copeland Compressor, R410A Refrigerant, Swep Heat Exchanger
WHY US:
Evi Air to Water Heat Pump with Copeland Compressor, R410A Refrigerant, Swep Heat Exchanger
KONNEN NEW PROJECTS:
Evi Air to Water Heat Pump with Copeland Compressor, R410A Refrigerant, Swep Heat Exchanger
WORLD FAMOUS BRAND WE COOPERATED FOR OUR HEAT PUMPS:
Evi Air to Water Heat Pump with Copeland Compressor, R410A Refrigerant, Swep Heat Exchanger
HEAT PUMP LOADING:
Evi Air to Water Heat Pump with Copeland Compressor, R410A Refrigerant, Swep Heat Exchanger
PRODUCT FEATURES:
Evi Air to Water Heat Pump with Copeland Compressor, R410A Refrigerant, Swep Heat Exchanger

PARAMETERS TABLE:
A02U series( EVI air source heat pump low temperature type)                                                                                                   EVI-150307
 EVI3P-S5EVI5P-S5EVI10P-C24EVI15P-C24EVI20P-C48EVI30P-C48EVI40P-C96
Normal conditionHeating capacitykW1219365575105145
Input powerkW2.80 4.40 8.20 12.70 17.10 24.10 33.20 
Input currentA5.30 8.60 14.80 24.20 33.00 45.10 62.50 
COP/4.29 4.32 4.39 4.32 4.39 4.36 4.37 
Nominal conditionRated heating capacitykW9.50 15.00 30.00 45.00 60.00 90.00 120.00 
Rated input powerkW2.60 4.10 8.10 12.20 16.10 24.50 32.50 
Rated input currentA5.20 8.20 15.30 23.10 30.20 46.00 61.10 
COP/3.65 3.66 3.70 3.68 3.73 3.67 3.69 
Low temperature conditionHeating capacitykW5.50 8.80 17.50 15.30 36.50 52.50 70.00 
Input powerkW2.26 3.65 7.30 6.41 15.10 21.60 29.10 
Input currentA4.29 6.93 13.00 12.10 28.10 40.80 54.80 
COP/2.43 2.41 2.40 2.39 2.42 2.43 2.41 
Maximum input power/currentkW/A3.61/6.925.71/11.2010.62/20.7516.52/32.2322.27/43.3631.38/61242.92/83.62
Rated hot water output temperatureºC55
Maximum hot water output temperatureºC60
Rated hot water produce capacityL/H204.25322.5645967.5129019352580
Power supply3N 380V/50Hz
CompressorTypeHermetic scroll type
Start modeDirectly start
Water side heat exchangerTypeShell & coil(tube) heat exchanger
Water flowM3/h2.1 3.3 6.0 9.5 12.9 18.0 24.9 
Water pressure dropKPa50556060656565
Pipe sizeDN25253232506565
Middle heat exchangerTypeBrazed plate type heat exchanger
Protections1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
NoiseDB(A)55586568707374
Unit dimensionsmm835×410×13301000×1000×18581000×2050
×1900
1000×2050
×1980
2000×2050
×1980
WeightKG1151753554256208551250
Testing condition: 1. Normal condition: dry bulb 20ºC, wet bulb 15ºC; initial water temperature 15ºC, end water temperature 55ºC.
                          2. Nominal condition: dry bulb 7
ºC, wet bulb 6ºC; initial water temperature 9ºC, end water temperature 55ºC.
                          3. Low temperature condition: dry bulb -12
ºC, wet bulb -14ºC; initial water temperature 9ºC, end water temperature 55ºC.

 
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours