Cast tube shell heat exchanger

Floating Head Heat Exchanger for SaleFloating head heat exchanger is one of the most used heat exchanger. As shown in the name of it, in this design, one end of the tubesheet is fixed to the shell, while the other one can "float" freely inside the shell. Generally, both the shell and tube bundle are free of expansion,

Featured Products

Floating Head Heat Exchanger for Sale
Floating head heat exchanger is one of the most used heat exchanger. As shown in the name of it, in this design, one end of the tubesheet is fixed to the shell, while the other one can "float" freely inside the shell. Generally, both the shell and tube bundle are free of expansion, this permits no thermal stress is produced between shell and tube bundle, when the temperature difference of two medium is large. In addition, it is easy to inspect and clean mechanically the heat exchanger as the tube bundle can be removed absolutely. Floating head heat exchanger is widely used for the service where the temperature is high between the shell and tube bundle, or the dirty service, like the petroleum refinery.
With high reliability and wide adaptability, floating head heat exchanger has accumulated a wealth of experience during the long - term using process, and promoted its development constantly. So far, among all kinds of heat exchangers, floating head heat exchanger is still in a leading position.
Floating Head Heat Exchanger Design
According to different requirements, the floating head on a floating head heat exchanger can be designed into various types, in addition to consider that the tube bundle can move freely within the device, we must also take into the convenience of maintenance, installation, and cleaning for the heat exchanger.
Generally, there are four basic types of floating head heat exchanger - outside packed stuffing box (TEMA P), outside packed lantern ring (TEMA W), the floating head with backing device (TEMA S), and pull through (TEMA T) designs.
ANSON can manufacturer various kinds of floating head heat exchangers accordance with the TEMA, API660, and JISB8249. Other special requirements are also available.
Cast Steel Shell & Tube Heat Exchanger

Main technical parameters of Fixed tube sheet type heat exchanger

 

 

NORMINAL  DIAMETERNORMINAL  PRESSURE   THE  PATH NO.OF TUBESNO. OF  TUBESNO. OF TUBES IN THE CENTERFLOWING      AREA OF THE TUBE SECTIONCALCULATION OF HEAT TRANSFER AREA
DNPNNn  m2
mmMpa   m2L=1500mmL=2000mmL=3000mmL=4500mmL=6000mmL=9000mm
1591.60     2.50     4.00     6.4011550.00271.31.72.6---
2193370.00582.83.75.7---
27316590.01155.47.411.317.122.9-
25680.00494.76.49.714.719.7-
325199110.01758.311.217.12634.9-
288100.00787.41015.223.131-
468110.0035.77.711.817.923.9-
4000.60      1.00       1.60      2.50       4.00  1174140.030714.519.730.145.761.3-
2164150.014513.718.628.443.157.8-
4146140.006512.216.625.338.351.4-
4501237170.041919.826.94162.283.5-
2220160.019418.42538.157.877.5-
4200160.008816.722.734.652.570.4-
5001275190.0486-31.247.672.296.8-
2256180.0226-2944.367.290.2-
4222180.0098-25.238.458.378.2-
6001430220.076-48.874.4112.9151.4-
2416230.0368-47.272109.3146.5-
4370220.0163-426497.2130.3-
6360200.0106-40.862.394.5126.8-
7001607270.1037--105.1159.4213.8-
2574270.0507--99.4150.8202.1-
4542270.0239--93.8142.3190.9-
6518240.0153--39.7136182.4-
8000.60       1.00      1.60      2.50      4.00  1797310.1408--138209.3280.7-
2776310.0686--134.3203.8273.3-
4722310.0319--125189.8254.3-
6710300.0209--122.9186.5250-
90011009350.1783--174.7265355.3536
2988350.0873--171259.5347.9524.9
4938350.0414--162.4246.4330.3498.3
6914340.0269--158.2240321.9485.6
100011267390.2239--219.3332.8446.2673.1
21234390.109--213.6324.1434.6655.6
41186390.0524--205.3311.5417.7630.1
61148380.0338--198.73.1404.3609.9
110011501430.2652---394.2528.6797.4
21470430.1299---386.1517.7780.9
41450430.0641---380.8510.6770.3
61380420.0406---362.4486733.1
120011837470.3246---482.5646.9975.9
21816470.1605---476.9639.5964.7
41732470.0765---454.9610920.1
61716460.0505---450.7604.3911.6
13000.25      0.60      1.00      1.60      2.5012123510.3752---557.6747.71127.8
22080510.1838---546.3732.51105
42074500.0916---544.7730.41101.8
62028480.0597---532.6714.21077.4

 

Main technical parameters of U type tube heat exchanger

 

NORMINAL DIAMETERTHE PATH NO. OF TUBESNO. OF TUBESNO. OF TUBES IN THE CENTERFLOWING AREA OF THE TUBE SECTION(m2)CALCULATION OF HEAT TRANSFER AREA  (m2)
DNNTUBE DIAMETER(mm)  dd×δtL=3000mmL=6000mm
mm 1925192519×225×225×2.519251925
325238131160.00670.00450.004113.462712.1
43012550.00270.00210.001910.65.621.311.2
426277321580.01360.01110.0126.914.754.529.8
40046828870.0060.00480.004423.812.948.226.1
50021285719100.02270.01970.017944.626.190.553
4114561090.01010.00970.008839.725.780.552.1
60021999423130.03520.03260.029569.142.9140.387.2
41849012110.01630.01550.014163.941.1129.783.5
700227612927150.04920.04530.0411--194.1119.4
425812812130.02280.02210.0201--181.4118.4
800236718231170.0650.0630.0571--257.7168
434617616150.03060.03040.0276--242.8162.5
900248023135190.0850.080.0725--336.2212.8
445422616170.04020.03910.0355--317.8208.2
1000260329839210.10670.10320.0936--421.5273.9
457629220190.0510.05050.0458--402.4268.4
1100273836343240.13060.12570.114--514.6332.9
470635620210.06250.06160.0559--492.2326.5
1200288543647260.15660.1510.1369--615.8399
485242824210.07540.07410.0672--592.6

Contact us